top of page
Generated image_ Futuristic Lab with Hexapod Device.png

REFRIGERANT-FREE • COMPRESSOR-FREE • ENERGY-GENERATING

Driving the future with clean energy solutions

Unitech turns cooling's waste heat into the electricity that runs it with no refrigerant, no compressor and no moving parts in the cooling circuit.

UK PATENT GB2316240.7

|

£1.07M INNOVATE UK · CRANFIELD & ASTON

|

EPTA PILOT · KYIV DATA CENTRE PILOT

ChatGPT Image Sep 22, 2026, 02_21_54 PM.png

WHY UNITECH EXISTS

Our mission.

Cooling judged on its full climate impact.

Cooling already uses around 10% of the world's electricity, and demand is set to triple by 2050. Under the Kigali Amendment, the HFC refrigerants most systems rely on are being phased down by 80–85%, leaving operators facing rising refrigerant costs and equipment that risks becoming stranded.

Unitech exists to make cooling that does not force that trade-off. We are inventing cooling cycles that run on plain air or natural CO₂, recover the energy conventional systems throw away, and are judged on their full climate impact (TEWI), not just their nameplate efficiency.

Read our impact case and the Kigali timeline →

80–85%

HFC phase-down under the Kigali Amendment

Air · CO₂

the working fluids our cooling cycles run on

TEWI

the measure we design to, not nameplate COP

ChatGPT Image Sep 22, 2026, 02_21_54 PM.png

01 - THE PROBLEM

Cooling pays twice.

Once for the electricity. Again for the refrigerant.

Every cooling system consumes power to create cold, then spends more energy rejecting the heat it creates. The refrigerants it relies on are also being phased down worldwide.

10%

of global electricity is consumed by cooling

3×

growth in cooling demand forecast by 2050

14,000×

the warming impact of the most potent HFCs versus CO₂ 

ChatGPT Image Sep 22, 2026, 02_21_54 PM.png

THE NAMEPLATE COP TRAP

Why TEWI, not nameplate COP.

A chiller can look efficient while its leaks add to its climate impact.

TEWI (Total Equivalent Warming Impact) counts both the direct emissions from refrigerant leakage and the indirect emissions from the electricity a system uses. Nameplate COP only measures the second. TEWI is the measure Unitech designs to.

See how TEWI compares across cooling systems →

10–25%

of their refrigerant charge is leaked by typical HFC systems every year

1,400+

global warming potential (GWP) of common HFCs, up to 3,922

GWP 1

for natural CO₂, the refrigerant INIJEVID V5 is built for

The industry does not need a better refrigerant. It needs a different cooling cycle.

waves
tovenor fan
data.png

Data Centres

Half the power drawn leaves as heat. Cooling is one of the largest loads in a data hall, and almost everything it removes is vented outside. TOVENVOR · INIJEVID returns that energy to the facility instead and a pilot system is running at a data centre in Kyiv now.

industrial.png

Industrial Refrigeration

Cold storage without the chemical liability. Process cooling and cold chain depend on refrigerants facing international phase-down, with disposal costs waiting at end of life. Ours uses none, removing F-Gas exposure from the balance sheet entirely.

asd 2.png

Commercial HVAC

The building's biggest load, working twice. Offices, retail and hospitality carry cooling as one of their largest operating costs and one of their largest carbon lines. Recovering the rejected heat addresses both at once.

ChatGPT Image Sep 22, 2026, 02_21_54 PM.png

03 - CO₂ RETROFIT KIT

The INIJEVID CO₂ Retrofit Kit.

Recover the energy the throttle valve throws away.

✓ Replaces the throttle valve: a bladeless, screw-studded radial-inflow expander fitted after the gas cooler on new or existing transcritical CO₂ racks.

✓ Two-stage cycle: expands from 90 to 62 bar into a separator that feeds a parallel compressor.

✓ Commercial validation underway: agreement in principle with global refrigeration leader EPTA for a targeted mid-2027 pilot.

✓ Built for: data centres, cold-chain and supermarket racks, and hot-climate district cooling.

F-Gas bans and the Kigali HFC phase-down are moving cooling onto transcritical CO₂. But above 31.1°C, the throttle valve in a CO₂ rack throws away the energy released as high-pressure gas expands, and efficiency falls as ambient temperatures rise. INIJEVID V5 recovers that lost energy.

+21%

COP at 32°C ambient (3.6 → 4.3). MODELLED

+30%

COP at 52°C ambient. MODELLED

PX G1300

drop-in replacement for the discontinued unit

ChatGPT Image Sep 22, 2026, 02_21_54 PM.png

04 - IMPACT

Solving cooling's climate crisis.

Social good and global regulatory tailwinds.

HFC refrigerants are among the most potent greenhouse gases in use, and the regulation phasing them out is already in force. EU F-Gas Regulation 2024/573 bans HFCs in domestic fridges from 2026.

See the full impact and validation story →

14,000×

HFC refrigerants trap up to 14,000× more heat than CO₂

400M+

HFC-containing cooling units enter end-of-life waste streams every year

250 Gt

CO₂e that IEA models show must be avoided from cooling by 2050

 06 - START A CONVERSATION

Let's build what comes next.

Whether you manufacture cooling systems, operate critical infrastructure or invest in climate technology, we'll route your enquiry to the right team.

Reason for Enquiry

We'll use your details to respond to your enquiry.

See our Privacy Policy

bottom of page